![]() ![]() Rigol DS6102 $7500usd, at 5GSa/s has 2 points at 1GHz, single ch, or 1pt both, 400ps rise times. is limited to 4GSa/s, Rigol DS6062 $5600usd, 5GSa/s has 3points at 600MHz, single ch, or 1.5pts both ch, 600ps rise times/200ps per division. shure some people need more the 1M wfm/s of the Agilent 3K for glitch detection, or the Big memory of the Tektronix DPO4K & Rigol DS4K Rigol DS4032 $3899usd. in this price range there is always a sacrifice, for me the Instek GDS-3352 had the balance between the performance vs. WaveSurfer Xs-B Oscilloscope Overview Videos. less than ideal memory is tolerable, low wfm/s is bad, low BW is worse, and low GSa/s is useless. The WaveSurfer MXs-B and MSO MXs-B oscilloscopes pack high performance hardware. Tektronix DPO4034B 350 MHz 4-channel Digital Phosphor Oscilloscope is $10,700usd. Much of the physics of the Player Series Acoustasonic Telecaster are just that, finding the happy medium between electric and acoustic design. DSOX2022A is limited to 200MHz, and 2GSa/s, with 100 kpts $2,215, yes it has more wfm/s but thats not all. In fact, the record length is perfectly predictable. i was looking for 5GSa/s minium with as High BW as i could get with as low ppm as my wallet allowed. The fact that the Siglent shows a 100 Mpts record length whereas the LeCroy only uses 5 Mpts has very little to do with the current memory management but with the limited memory of just 25 Mpts per channel pair on his LeCroy Wavesurfer 104MXS-B. and i hate the software frequency counter. at 5GSa/s anything less than 10MPoints is not enough. not even a fully maxed out Agilent DSOX3K problem with Agilent DSOX3K is the 4 GSa/s & the 2MPoints Memory, or 5GSa/s & 4Mpts in the 1GHz version, 2ch $9,965 4ch $13,020usd. i would have bought LeCroy WaveSurfer 104MXs-B 1GHz 4ch 10GSa/s, 32 Mpts Interleaved, 22.000wfm/s, 10" Touch Screen. The "Low Memory" 25k points and the Medium range wfm/s "85x better than Owon Top of the Line", were enough for me, considering the price i payd, shure, if i had $17.OOOusd. Sweep time - for span >10 Hz: 2.Dave or No Dave i purchased a GDS-3352, the only scope that offers 350MHz 5GSa/s 75ohm, with low ppm under $10Kusd.Maximum dynamic range and minimum phase noise.Fully and partially automatic measurements (preview measurement, data reduction, final measurement).2 million test points, measurement time =10 µs/point) CISPR- and MIL-STD-compliant measurement bandwidths.Integrated low-noise 30 dB preamplifier up to 40 GHz optional available.Full compliance with CISPR 16-1-1 standard.The R&S®ESU also features automatic and interactive measurement functions, parallel IF analysis and up to three detectors in parallel including the average detector with meter time constant (CISPR-Average), RMS-Average detector, and APD (amplitude probability distribution to CISPR 16). The R&S®ESU-K53 FFT-based time-domain scan option allows users to perform overview measurements up to 1000 times faster than on standard EMI test receivers. Oscilloscopes - Touch Screen Oscilloscope - WaveSurfer 104MXs-B. Includes MS-250 Mixed Signal Oscilloscope Module. The R&S®ESU is a family of CISPR 16-1-1-compliant EMI test receivers that meet all civil and military standards for electromagnetic disturbance measurements. Description: The WAVESURFER 434 is a 350 MHz, 4 channel digital oscilloscope from. The WaveSurfer MSO 104MXs-B Mixed Signal Oscilloscope packs high performance hardware, powerful waveform processing and advanced math, measurement and debug tools into a compact form factor with a large touch screen display and intuitive user interface. ![]() ![]() Optional low-noise preamplifiers up to 8/26.5/40 GHz (R&S®ESU-B24).Fast and reliable measurements using automatic and interactive test routines The WaveSurfer 104MXs-B is a 1 GHz,5 GS/s,4ch,16 Mpts/Ch DSO with 10.4' Color Touch Screen Display.10GS/s,32 Mpts Interleaved oscilloscope. The frequency is controlled by WFG and set in a range between 100 and.The client told me that he received a call from someone in Kansas City. Time-domain analysis for evaluation of timing behavior of disturbances (e.g. Im actually having the exact issue with a client of mine located in Dallas, TX.Receiver mode with parallel IF analysis.Integrated 20 dB preamplifier up to 3.6 GHz as standard.Internal preselection (can be switched off in analyzer mode).All commercial and military standards met.High speed time domain scan (FFT) option.Combination of CISPR 16-compliant EMI test receiver and high-end spectrum analyzer.Maximum-precision, standard-compliant EMI measurements at unparalleled measurement speed ( own it? please share by Add Your Own Review! ) ![]()
0 Comments
Leave a Reply. |